{"product_id":"st-301-spider-power-wireline-mains-analyzer","title":"ST 301 Spider Power Wireline \u0026 Mains Analyzer","description":"\u003cp\u003eThe Analyzer is designed to detect and localize eavesdropping devices that are galvanically connected to power mains and low-current cables.\u003c\/p\u003e\r\n\u003cp\u003eIn the ST 301, passive and active modes of operation are used to detect enabled, switched off, or faulty eavesdropping devices.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong style=\"font-size: 1.5em;\"\u003eApplication\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eFunctionally the Analyzer consists of four components (DEVICES):\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003e1. LOW FREQUENCY AMPLIFIER (LFA)\u003c\/p\u003e\r\n\u003cp\u003e2. WIRE RECEIVER (WR)\u003c\/p\u003e\r\n\u003cp\u003e3. NON-LINEAR JUNCTION DETECTOR (NLJD)\u003c\/p\u003e\r\n\u003cp\u003e4. REFLECTOMETER (REF)\u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cdiv class=\"table\"\u003e\r\n\u003ctable class=\"table-prop\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eHeight\u003c\/td\u003e\r\n\u003ctd class=\"value\"\u003e165 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eWidth\u003c\/td\u003e\r\n\u003ctd class=\"value\"\u003e98 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eThickness\u003c\/td\u003e\r\n\u003ctd class=\"value\"\u003e40 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eWeight\u003c\/td\u003e\r\n\u003ctd class=\"value\"\u003e470 g\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003c\/div\u003e\r\n\u003cp\u003eDelivery set:\u003c\/p\u003e\r\n\u003cp\u003e\u003cbr\u003e\u003cspan\u003e1. Main unit\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e2. Charger of the main unit\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e3. Flash card \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e4. Mini-USB patch cord\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e5. Television splitter\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e6. Headphones\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e7. Adapter for testing of the power mains\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e8. TV(m)\/F(m) adapter\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e9. TV(f)\/F(m) adapter\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e10. TV(f)\/TV(f) adapter\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e11. RJ11 (1\/2) splitter \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e12. RJ45 (1\/2) splitter \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e13. RJ11 socket \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e14. RJ45 socket\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e15. RJ45 short-circuit socket\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e16. Adapter and screwdriver for connecting to the multi-wire cable\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e17. Cable storage bag\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e18. Television cable TV(f)\/TV(m) \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e19. Patch cord RJ45\/TV(m) for connecting to the TV socket TV(f)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e20. Patch cord for connecting to the RJ45 PC socket\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e21. Patch cord for connecting to the RJ11 telephone socket\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e22. Patch cord with a needle for connection to the cable shield\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e23. Case\u003c\/span\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eFunctionality:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003edetection and the analysis of signals cable (dynamic and electret) microphones in low-current cables;\u003c\/li\u003e\r\n\u003cli\u003eactivation of electret cable microphones by giving to the cable of bias voltage for their detection;\u003c\/li\u003e\r\n\u003cli\u003edetection of signals of the eavesdropping devices transferring information on power mains and low-current cables in frequency range of 100 kHz - 180 MHz;\u003c\/li\u003e\r\n\u003cli\u003edetection of unauthorized galvanic connections to the cables using a NLJD and the REF;\u003c\/li\u003e\r\n\u003cli\u003emeasurement of AC and DC voltage in the low-current cables.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"2\"\u003e\r\n\u003cp\u003e\u003cstrong\u003eLOW FREQUENCY AMPLIFIER (LFA)\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eFrequency range, Hz\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e20 - 25000\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eInput resistance, kOhm\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e200\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eAdjustment range of gain, dB\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e0 - 60\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eThe maximum signal amplitude on an input, V\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e10\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eSpectral density of noise voltage, nV\/Hz\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e6\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eBias voltage values, V\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e0, ±5, ±10,\u003c\/p\u003e\r\n\u003cp\u003e±15, ±20, ±26\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eForm of representation of a signal\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eOscillogram\u003c\/p\u003e\r\n\u003cp\u003eSpectrogram\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eMeasurement range on a direct current, V\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e±80\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"2\"\u003e\r\n\u003cp\u003e\u003cstrong\u003eWIRE RECEIVER (WR)\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eFrequency range, MHz\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e0.1 - 180\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eTime of scanning of all range, sec\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e0.3 - 1\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eMinimum level of detected signal in AUTOMATED mode, dBm\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e-60\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eDynamic range, dB\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e50\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eInput resistance, Ohm\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e50\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eDemodulation\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eAM, FM\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eBandwidth of the filter, kHz\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e180\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eThe maximum allowed voltage in the cable, V\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e250 (AC),80 (DC)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eData representation form\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eSpectrogram\u003c\/p\u003e\r\n\u003cp\u003eOscillogram\u003c\/p\u003e\r\n\u003cp\u003eTable\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"2\"\u003e\r\n\u003cp\u003e\u003cstrong\u003eNON-LINEAR JUNCTION DETECTOR (NLJD)\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eLevel (amplitude) of the probing signal, V\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e±14\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eFrequency of the probing signal, Hz\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e60\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eSeparate indication of even and odd harmonics\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eyes\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eMinimum detectable level of non-linear distortion, %\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e0.1\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"2\"\u003e\r\n\u003cp\u003e\u003cstrong\u003eREFLECTOMETER (REF)\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eRange of distances, m\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e3 - 150\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eError of measurements, m\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e±0,6\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eThe ability to work on cables under voltage\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eno\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"2\"\u003e\r\n\u003cp\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eThe built-in lithium-polymer accumulator, V\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e3.7\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003ePower consumption, W\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e\u0026lt;1\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eOperating time at the maximum power consumption, hour\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e\u0026gt;3\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eCharging interval of completely discharged accumulator, hour\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e5\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"2\"\u003e\r\n\u003cp\u003e\u003cstrong\u003eWeight and dimensions\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eDimensions of the main unit (length, width, height), mm\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e165 x 98 x 40\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eMass of the main unit, kg\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e0.47\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003ePackaging dimensions (length, width, height), mm\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e390 x 310 x 170\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eMass of the kit in packaging, kg\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e4.4\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e","brand":"Spy Gear Store","offers":[{"title":"Default Title","offer_id":50046829723925,"sku":"SEL-ST301","price":14995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0881\/3074\/8693\/files\/ST301_Spider_2__92257.1623354782.jpg?v=1784475343","url":"https:\/\/spygearstore.com\/products\/st-301-spider-power-wireline-mains-analyzer","provider":"SpyGearStore.com","version":"1.0","type":"link"}